ZK -SAMp Uživatelský manuál Strana 26

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 25
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Close and Reverse State: Set locking or not after door closing. Tick it for lock after door closing.
Verify Mode: Identification modes include Only Card, Card plus Password, Only Password, Card plus Fingerprint, and Only
Fingerprint verify. The default is Only Card or Only Fingerprint. When Card plus Password mode is selected, make sure the
door uses a reader with keyboard (the fingerprint verify modes are only available for version 5.0.8 and above);
Duress Password, Emergency Password: Upon duress, use Duress Password (used with legal card) to open the door.
When opening the door with Duress Password, it will alarm. Upon emergency, the user can use Emergency Password (named
Super Password) to open the door. Emergency Password allows normal door opening. Emergency Password is effective in
any time zone and any type of verify mode, usually used for the administrator.
Duress Password Opening (used with legal card): When Only Card verify mode is used, you need to press [ESC] first and
then press the setting password plus [OK] button. Finally swipe your card. The door opens and triggers the alarm. When Card
plus Password verify mode is used, swipe your card first then press the password number plus the [OK] button (same to
normal door open in card plus password verify mode). The door opens and triggers the alarm.
Emergency Password Opening: The password must be a number not exceeding 8 digits (integers). The door can be opened
just by entering the password. Press [ESC] every time before entering password then press OK to execute.
When using Duress Password or Emergency Password, the interval for entering each number shall not exceed 10 seconds
and these two numbers should not be the same.
Apply these settings to all the doors of current access control panel: Click to apply to all doors of the current access
control panel;
Apply these settings to all the doors of all access control panels: Click to apply to all doors of all access control panels
within the current user’s level;
After parameter editing, click [OK] to save and quit.
6.3.2 First-Card Normal Open
First-Card Normal Open: During a specified interval, after the first verification by the person having First-Card Normal Open
level, the door will be Normal Open and will automatically restore closing after the valid interval expires.
The user can set First-Card Normal Open for a specific door. The settings include door, door opening time zone and personnel
with First-Card Normal Open level. A door can have First-Card Normal Open settings for multiple time zones. The interface of
each door will show the number of existing First-Card Normal Open settings. For First-Card Normal Open setting, when
adding or editing each record, it is not required to modify the “current door” but is to select time zone. When record adding is
successful, add personnel that can open the door for a First-Card Normal Open setting record. On the right of the interface you
can browse door opening personnel in a First-Card Normal Open setting and delete current personnel, so that some
personnel will not have First-Card Normal Open level any more.
The operation steps are as follows:
1. Click [Set] under “First-Card Normal Open” of a door to show First-Card Normal Open setting interface;
2. Click [Add], select the time zone of First-Card Normal Open, and click [OK] to save the settings;
3. Click [Add an opening person] under Related Operation” to set personnel having First-Card Normal Open level.
Click [OK] to save and quit editing.
Note: For a door currently in Normal Open time period, consecutive verification of a person having access level for the
door for 5 times (the person verification interval should be within 5 second) can release the current Normal Open status and
close the door. The sixth person verification will be a normal verification. This function is only effective at the valid door time
zone. Normal Open intervals set for other doors within the day and First-Card Normal Open settings will not take effect
anymore.
6.3.3 Multi-Card Opening
This function needs to be enabled in some special access occasions where the door will open only after the consecutive
verification of multiple people. Any person verifying outside of this combination (even if the person belongs to other
combinations) will interrupt the procedure, requiring a 10 second wait to restart verification. It will not open by verification of
only one of the combination.