ZK -SAMp Uživatelský manuál Strana 34

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 33
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
door open period after the first card normally open), or through the remote normal open operation, the person has open door
permission, punch the effective card at the opened door to trigger this normal event.
Press Fingerprint During Normal Open Time Zone: At the normally open period (set to normally open period of a single
door or the door open period after the first card normally open), or through the remote normal open operation, the person has
open door permission, press the effective fingerprint at the opened door to trigger this normal event.
First Card Normal Open (Punch Card): In [Card Only] verification mode, the person has first card normally open permission,
punch card at the setting first card normally open period but the door is not opened, and trigger the normal event.
First Card Normal Open (Press Fingerprint): In [Fingerprint Only] or [Card plus Fingerprint] verification mode, the person
has first card normally open permission, press the fingerprint at the setting first card normally open period but the door is not
opened and triggers the normal event.
First Card Normal Open (Card plus Fingerprint): In [Card plus Fingerprint] verification mode, the person has first card
normally open permission, punch the card and press the fingerprint at the setting first card normally open period but the door is
not opened and triggers the normal event.
Normal Open Time Zone Over: After the setting normal open time zone, the door will close automatically. The normal open
time zone includes the normal open time zone in door setting and the selected normal open time zone in first card setting.
Remote Normal Opening: Set the door state to normal open in the remote opening operation and trigger this normal event.
Cancel Normal Open: Punch the valid card or use remote opening function to cancel the current door normal open state and
trigger this event.
Disable Intraday Normal Open Time Zone: In door normal open state, punch the effective card five times near the card
reader (must be the same user), or select [Disable Intraday Normal Open Time Zone] in remote closing operation and trigger
this normal event.
Enable Intraday Normal Open Time Zone: If the intraday door normal open time zone is disabled, punch the effective card
five times near the card reader (must be the same user), or select [Enable Intraday Normal Open Time Zone] in remote
opening operation and trigger this normal event.
Multi-Card Open (Punching Card): In [Card Only] verification mode, multi-card combination can be used to open the door.
After the last card is verified, the system triggers this normal event.
Multi-Card Open (Press Fingerprint): In [Fingerprint Only] or [Card plus Fingerprint] verification mode, multi-card
combination can be used to open the door. After the last fingerprint is verified, the system triggers this normal event.
Multi-Card Open (Card plus Fingerprint): In [Card plus Fingerprint] verification mode, multi-card combination can be used to
open the door. After the last card plus fingerprint is verified, the system triggers this normal event.
Multi-Card Open (Press Fingerprint): In [Card Only] verification mode, multi-card combination can be used to open the door.
After the last fingerprint is verified, the system triggers this normal event.
Multi-Card Open (Card plus Fingerprint): In [Card Only] verification mode, multi-card combination can be used to open the
door. After the last card plus fingerprint is verified, the system triggers this normal event.
Emergency Password Open: The password (also known as the super password) set for the current door can be used for
door open. It will trigger this normal event after the emergency password is verified.
Open during Normal Open Time Zone: If the current door is set a normally open period, the door will open automatically
after the setting start time and trigger this normal event.
Linkage Event Triggered: After the system linkage configuration takes effect, this normal event is triggered.
Cancel Alarm: When the user cancels the alarm of the corresponding door and the operation is a success, this normal event
is triggered.
Remote Opening: When the user opens a door by remote and the operation is successful, it will trigger this normal event.
Remote Closing: When the user closes a door by remote and the operation is successful, it will trigger this normal event.
Open Auxiliary Output: In linkage action setting, if the user selects Auxiliary Output for Output Point Address and selects
Open for Action Type, it will trigger this normal event when the linkage setting takes effect.
Close Auxiliary Output: In linkage action setting, if the user selects Auxiliary Output for Output Point Address and selects
Open for Action Type, it will trigger this normal event when the linkage setting takes effect and if the user closes the opened
auxiliary output through the [Close Auxiliary Output] operation in [Door Setting], this normal event triggers too.