Door Opened Correctly: When the door sensor detects that the door has been properly opened, this normal event is
triggered.
Door Closed Correctly: When the door sensor detects that the door has been properly closed, this normal event is triggered.
Auxiliary Input Disconnected: When the auxiliary input point is disconnected, this normal event is triggered.
Auxiliary Input Shorted: When the auxiliary input point is short circuited, this normal event is triggered.
Device Start: When the device starts, this normal event is triggered.. This event cannot be displayed on the real-time monitor
but it can be checked in the event report.
2. Abnormal Events
Too Short Punch Interval: When the interval between two card punches is less than the set time interval, this abnormal event
is triggered.
Too Short Fingerprint Pressing Interval: When the interval between two card punches is less than the set time interval, this
abnormal event is triggered.
Door Inactive Time Zone (Punch Card): In [Card Only] verification mode, the user has the door open permission and
punches the card but not within the door effective period of time, this abnormal event is triggered.
Door Inactive Time Zone (Press Fingerprint): The user has the door open permission and presses the fingerprint but not
within the door effective period of time, this abnormal event is triggered.
Door Inactive Time Zone (Exit Button): The user has the door open permission and punches the card but not within the
access effective period of time, this abnormal event is triggered.
Illegal Time Zone: A user with permission to open the current door punches the card during the invalid time zone triggers this
abnormal event.
Access Denied: A registered card without access permission for the current door punches to open the door triggers this
abnormal event.
Anti-pass Back: When the Anti-pass Back Setting of the system takes effect, this abnormal event is triggered.
Interlock: When the interlocking rules of the system take effect, this abnormal event is triggered.
Multi-Card Authentication (Punching Card): Use Multi-Card Combination to open a door, the card verification before the
last one (whether verified or not), triggers this normal event.
Multi-Card Authentication (Press Fingerprint): Use Multi-Card Combination to open a door, the fingerprint verification
before the last one (whether verified or not), triggers this normal event.
Multi-Card Authentication (Punching Card): Use Multi-Card Combination to open a door, the card verification before the
last one (whether verified or not), triggers this normal event.
Multi-Card Authentication (Press Fingerprint): In [Fingerprint Only] or [Card plus Fingerprint] verification mode, use
Multi-Card Combination to open a door, the fingerprint verification before the last one (whether verified or not), triggers this
normal event.
Unregistered Card: If the current card being used is not registered in the system, this abnormal event is triggered.
Unregistered Fingerprint: If the current fingerprint is not registered or it is registered but not synchronized with the system,
this abnormal event is triggered.
Opening Timeout: If the door sensor detects that the delay time after open has expired, the door is closed and this abnormal
event is triggered.
Card Expired: The person with the door access permission punches the card to open the door after the effective time of the
access control and cannot be verified, this abnormal event will trigger.
Fingerprint Expired: The person with door access permission presses fingerprint to open the door after the effective time of
the access control and cannot be verified, this abnormal event will trigger.
Password Error: Use Card plus Password, Duress Password or Emergency Password to open the door, this event is
triggered if the password is wrong.
Failed to Close during Normal Open Time Zone: If the current door is in normal open state but the user can not close the
door through [Remote Closing] operation, this abnormal event is triggered.